- Online only
LEAD BATTERY CHARGERS SKB SK6 - 1,3
Usage: emergency lights, general electronics
Usage: emergency lights, general electronics
The SKB lead batteries are lead-acid batteries in recombination, even if they are called hermetic. This manufacturing technology allows the battery to effetturare ca. 200/300 cycles at 100% depth of discharge, while at 30% of its capacity reaches 1000 cycles.For proper operation of the battery you must adhere to certain requirements.CHARGE: The charge must be made with a constant voltage charger strictly follow the information on the battery. An incorrect voltage may lead to the immediate deterioration of the battery. Must not be left discharged after his utlizzo, but it needs to be charged immediately.DOWNLOAD: it must not be brought, during the discharge phase, to a voltage lower than 5,25Volt for a 6V battery, 10,50Volt for a 12 Volt battery.WARNING: The battery contains sulfuric acid. Care must be taken when it is manipulated. In case of accidental contact with the acid not touch your eyes it's mouth. Wash immediately with running water. Go to the hospital emergency room.The battery must be disposed of according to current regulations Voltage: 6 VCapacity: 1.3 AhStandard Charge Current: max. 1/3 of the capacityCharging voltage buffer: 6.75 to 6.90 VCharging voltage cyclic use: 7.35 to 7.50 VDimensions: W x D x H - HT: 98 x 24 x 52-56 mmFaston terminals: 4.8 mmWeight: 0.3 Kg